Quick answer
For each line on your report, check the units, the result and the limit it's compared against. Health-based results come first: any E. coli or total coliform, nitrate above 10 mg/L, arsenic above 10 µg/L, uranium above 30 µg/L, or lead above 15 µg/L. Aesthetic results such as iron above 0.3 mg/L or manganese above 0.05 mg/L cause stains and taste but aren't a health risk at those levels. A "less than" sign means the lab didn't detect it.
- Best for
- Well owners holding a lab report who want to know which numbers matter, which are fine, and what to do next.
- Wrong fit
- Anyone holding only a salesperson's in-home test or a strip reading. Get a certified lab test first, then use this guide.
- Tradeoff
- EPA limits are written for public water systems. They're the right benchmark for a private well, but no agency enforces them on your well.
How a report is laid out
Most lab reports have the same columns. Penn State Extension walks through them in its guide to interpreting test reports:
- Sample information. Your name, the lab ID, when and where the sample was collected. Check the collection date and location. A sample from the pressure tank tells you about raw well water; a kitchen tap sample shows what you drink after any treatment.
- Analysis. What was tested.
- Units. mg/L, µg/L, MPN/100 mL and so on.
- Result. Your number.
- Standard. The limit your result is compared against, and whether it is health-based or aesthetic.
- Method. The EPA or standard method the lab used. Certified labs have to use approved methods.
Some reports also flag results that exceed a standard and list a contact for questions.
Units and symbols
| On the report | Means | Same as |
|---|---|---|
| mg/L | milligrams per liter | parts per million (ppm) |
| µg/L | micrograms per liter | parts per billion (ppb); 1,000 µg/L = 1 mg/L |
| gpg | grains per gallon (hardness) | 1 gpg = 17.1 mg/L as CaCO3 |
| MPN/100 mL or CFU/100 mL | bacteria count per 100 mL | |
| P/A | present or absent (bacteria) | |
| < 0.003 | not detected above the lab’s detection level | treat as “not found” |
| > 201 | above the highest amount the method can count | a high result |
| pCi/L | picocuries per liter (radioactivity) |
Penn State explains that labs don’t report zero. When nothing is found, the result is shown as “less than” the detection level. A “greater than” sign on bacteria means more colonies than the method can count.
Watch the unit before you compare. Arsenic at “0.008” in mg/L is 8 µg/L, under the 10 µg/L limit. The same “8” in mg/L would be a thousand times higher. Nitrate limits are written “as nitrogen.” Check that your lab reports it the same way.
Health-based results: act on these first
These limits come from EPA’s National Primary Drinking Water Regulations for public water systems. They’re the standard benchmark for private wells too.
| Parameter | Limit | If you’re over it |
|---|---|---|
| E. coli | Must be absent | Stop drinking it; boil or use bottled water; call your health department; shock chlorinate and fix the well |
| Total coliform | Should be absent | Use bottled or boiled water; shock chlorinate; retest |
| Nitrate (as N) | 10 mg/L | Don’t use for infant formula; use bottled water; find the source; consider RO |
| Nitrite (as N) | 1 mg/L | Same as nitrate |
| Arsenic | 0.010 mg/L (10 µg/L) | Use other drinking water; RO or other treatment |
| Uranium | 30 µg/L | Use other drinking water; treatment needed |
| Lead | 15 µg/L action level (10 µg/L from Nov. 1, 2027) | Stop drinking it; take a first-draw retest; check pH |
| Copper | 1.3 mg/L action level | Use other drinking water; check pH |
| Fluoride | 4.0 mg/L | Use other drinking water for children |
| Radium 226 + 228 | 5 pCi/L | Call your state health department |
| Manganese | 0.3 mg/L (EPA health advisory, not a regulation) | Treat drinking water; extra caution for infants |
EPA says infants under six months who drink water with nitrate above 10 mg/L could become seriously ill. For manganese, EPA’s health advisory document flags concern for infants, and the Minnesota Department of Health uses a guidance value of 100 µg/L for infants who drink tap water or formula made with it, and 300 µg/L for everyone over one year old.
For any result in this table, call your state health department. They can tell you how urgent it is and whether to retest. See bacteria, nitrate, arsenic and manganese.
Aesthetic results: stains, taste and scale
These are EPA’s secondary standards. EPA calls them guidelines and does not enforce them. They mark where cosmetic and aesthetic problems usually start.
| Parameter | Secondary standard | What you notice |
|---|---|---|
| Iron | 0.3 mg/L | Rusty color, sediment, metallic taste, reddish or orange stains |
| Manganese | 0.05 mg/L | Black to brown color, black stains, bitter metallic taste |
| pH | 6.5 to 8.5 | Low: bitter metallic taste, corrosion; high: slippery feel, soda taste, deposits |
| Total dissolved solids | 500 mg/L | Hardness, deposits, colored water, staining, salty taste |
| Sulfate | 250 mg/L | Salty taste |
| Chloride | 250 mg/L | Salty taste |
| Copper | 1.0 mg/L | Metallic taste, blue-green staining |
| Color | 15 color units | Visible tint |
| Odor | 3 threshold odor number | Rotten-egg, musty or chemical smell |
Iron below 0.3 mg/L may need nothing at all. More on iron in well water.
Results with no EPA number
Some useful results don’t have a federal limit:
- Hardness. Penn State classes water from soft (below 1 gpg [17 mg/L]) to very hard (above 10.5 gpg [180 mg/L]), with 7.0 to 10.5 gpg [120 to 180 mg/L] counted as hard. See hard well water.
- Hydrogen sulfide. No drinking water standard, because the smell makes water undrinkable well before it is harmful. Penn State says most people smell it well below 0.5 mg/L. The sample must be stabilized or tested on site.
- Corrosivity index (LSI). Penn State says negative values indicate corrosive water. Pair it with a first-draw lead and copper test.
- Sodium. Useful if anyone in the home is on a low-sodium diet, especially if you soften.
A worked example
Here is an illustrative report for a well with common nuisance problems. The numbers are an example, not real data.
| Analysis | Units | Result | Limit | Reading it |
|---|---|---|---|---|
| Total coliform | MPN/100 mL | <1 | absent | Not detected. Good. |
| E. coli | MPN/100 mL | <1 | absent | Not detected. Good. |
| Nitrate as N | mg/L | 2.1 | 10 | Well under the limit |
| Arsenic | mg/L | <0.003 | 0.010 | Not detected at the lab’s detection level |
| pH | 6.3 | 6.5 to 8.5 | Slightly acidic; check copper and lead | |
| Iron | mg/L | 2.4 | 0.3 | Eight times the aesthetic level; expect orange stains |
| Manganese | mg/L | 0.12 | 0.05 | Above the aesthetic level, below EPA’s 0.3 health advisory |
| Hardness | mg/L as CaCO3 | 205 | none | About 12 gpg, very hard |
| TDS | mg/L | 310 | 500 | Fine |
What this report says, in order:
- No health emergency. Bacteria, nitrate and arsenic are fine.
- Low pH comes first in treatment. At 6.3 it’s below the secondary range and below what some iron filters require. Penn State notes negative corrosivity and low pH go with corroded plumbing, so test first-draw lead and copper.
- Iron and manganese next. Both are above the staining levels.
- Hardness last. A softener goes after the iron filter, and a calcite neutralizer would add a bit more hardness.
The treatment order would be neutralizer, then iron and manganese filter, then softener.
Red flags on a report
- No lab name or certification. Penn State stresses that state-accredited labs are vital for accurate, unbiased results.
- No units, or units you can’t match to a limit.
- No method column. Penn State notes methods are required as part of state lab accreditation.
- A report from the company selling you equipment with no independent lab behind it.
- A bacteria result from a sample that sat for days before reaching the lab.
Turning results into a plan
- Health results over a limit: switch drinking water now, then retest to confirm and call your health department.
- Bacteria only, no E. coli, first time: shock chlorinate and retest before buying equipment. See how to test well water for sampling steps.
- Several aesthetic problems: treatment order matters. Sediment, then pH, then iron, manganese and sulfur, then softening, then UV.
- Missing results: if your report lacks iron, manganese, hardness or pH and you’re planning treatment, add them before you buy anything.
Enter your numbers at /test-results/ to get a treatment plan built from them.
Common questions
What does ND or a less-than sign mean on a water test?
It means the lab didn't find the substance above its detection level. Penn State Extension explains that labs report 'less than' the lowest amount their instrument can read instead of reporting zero.
Is mg/L the same as ppm?
Yes, for drinking water. One mg/L equals one part per million (ppm), and one µg/L equals one part per billion (ppb). There are 1,000 µg/L in 1 mg/L.
What is a good TDS level for well water?
EPA's secondary standard for total dissolved solids is 500 mg/L. Higher levels can cause taste and staining problems. Penn State suggests watching for changes from one test to the next, since a rise can signal pollution.
What does MPN mean on a bacteria test?
It stands for 'most probable number,' an estimate of bacteria per 100 mL of water. For total coliform and E. coli, the target is zero.
What manganese level is safe in well water?
EPA's lifetime health advisory is 0.3 mg/L. Minnesota's health department uses a lower guidance value of 100 µg/L (0.1 mg/L) for infants who drink tap water or formula made with it.
Read next
- How to test well waterWhat to test your well for, how to pick a certified lab, and how to take bacteria, lead and raw-water samples so the results are worth acting on.
- Bacteria in well waterA positive coliform test is common and often fixable. What total coliform and E. coli results mean, when to shock chlorinate, and when UV is worth it.
- Nitrate in well waterNitrate above 10 mg/L is unsafe for babies under six months. What your result means, why boiling makes it worse, and how reverse osmosis fits.
- Iron in well waterOrange stains mean iron. What level needs treatment, how to test, and which filter fits your numbers, from doing nothing to chemical injection.
Sources
- EPA: National Primary Drinking Water Regulations
- EPA: Secondary Drinking Water Standards
- EPA: Drinking Water Health Advisory for Manganese (PDF)
- Minnesota Department of Health: Manganese in Drinking Water
- Penn State Extension: Interpreting Your Water Test Report
- Penn State Extension: Water Softening
- Penn State Extension: Corrosive Water Problems
- Penn State Extension: Hydrogen Sulfide (Rotten Egg Odor) in Water Wells